Air Conditioner Coolant Leak? How to Judge it Yourself?
Air conditioners are heat movers. More specifically, refrigerants, also known as coolant, are the heat movers. Refrigerants flow through air conditioning ducts, moving heat from the room to the outside, achieving the purpose of “cooling.”
Anyone who’s ever repaired an air conditioner knows that nine out of ten times, the problem is a lack of refrigerant.
The so-called “lack of freon” simply means a reduction in the refrigerant in the pipes. But refrigerant isn’t a consumable item; if it’s running smoothly through the pipes, how could it possibly decrease?

To put it bluntly, “re-coolant” is a major profit maker for air conditioner repairmen. They just set up a pressure tank nearby, wait for ten minutes, and charge a hundred yuan—a lucrative job anyone would take.
So, if your air conditioner breaks down, don’t rush to call after-sales service. Check yourself to see if you’re truly deficient in coolant. Knowing the answer will help you avoid wasting money.
Air conditioner repairmen use the “freon leak” scam as a main way to make money. They charge a hundred yuan for a wait time of just ten minutes—a lucrative job anyone would take.
So, if your air conditioner breaks down, don’t rush to call after-sales service. Check yourself to see if the problem is truly a Freon leak. Knowing the answer will help you avoid wasting money.
Generally speaking, if an air conditioner is lacking in coolant, there will be the following six symptoms – if two or more of the symptoms are met, it can basically be determined to be lacking in refrigerant.

1. Fault Code Displayed
The air conditioner has a self-diagnosis program for refrigerant, but this isn’t entirely accurate. A fault code will only display when the pressure in the pipes is very low, indicating a severe refrigerant shortage.

Furthermore, the fault code will not be displayed when the machine is just turned on, but will often be displayed after it has been running for a while. Different brands have different fault codes, but one thing is the same: after the fault code is displayed, the machine will stop working immediately, and this fault code will be displayed every time the machine is turned on.
2. The air outlet temperature is too high
Air conditioners rely on refrigerant for cooling. When refrigerant is deficient, the air conditioner’s cooling efficiency decreases. The most obvious sign of this decrease in cooling efficiency is an increase in the air outlet temperature.
Generally speaking, the air outlet temperature of an air conditioner will not exceed 17°C when it is first turned on (the highest outlet temperature is 17°C when set to 30°C). The higher the outlet temperature, the more severe the refrigerant deficiency. If the air conditioner’s fault code is triggered, as mentioned earlier, the air outlet temperature will generally be similar to the room temperature.
3.Smaller temperature difference between inside and outside
When the indoor unit of an air conditioner blows cold air, the outdoor unit blows hot air. Measuring the temperature difference between the air flowing out of the indoor and outdoor units can provide a more intuitive assessment of the air conditioner’s cooling performance.
Normally, the temperature difference between the indoor and outdoor units should be no less than 8°C. If the temperature difference decreases, the air conditioner’s cooling performance is deteriorating. This decline is caused by a coolant leak. The more severe the coolant leak, the smaller the temperature difference.
4. Frost on the High-Pressure Valve
There are two yellow copper valves on the lower left side of the outdoor unit. They are of different sizes: the larger one is the low-pressure valve; the smaller one is the high-pressure valve.

When the air conditioner is deficient in fluorine, frost will form on the surface of the high-pressure valve after a period of operation. The surface of the low-pressure valve will become dry and not cold to the touch.
(When inspecting the outdoor unit of the air conditioner, please pay attention to personal safety. Those living in high-rise buildings should never climb out of the window on their own.)
5. Prolonged No-Stop Operation
A fixed-frequency air conditioner’s outdoor unit shuts down when the room temperature drops; an inverter air conditioner reduces its power when the room temperature drops. So, after turning on the air conditioner for 20 minutes, check the outdoor unit to see if it’s still running at full speed.
If it is, there’s a problem—the room temperature hasn’t dropped after 20 minutes. This indicates excessively slow cooling, and one possible cause of this is a coolant leak.
6. Pipeline Leakage
When relocating an air conditioner, the pipes often need to be replaced. During this process, the worker will ask, “Copper or aluminum?”

These metal pipes contain refrigerant. A small hole in the pipe, a broken joint, or a poorly connected valve can cause refrigerant to leak.
Also, the air conditioner compressor contains compressor oil, which protects the pipes. This oil is normally contained within the pipes, so if a pipe is damaged, it will leak oil along with the coolant.
Inspect the pipes to see if there are any areas of contamination or oil leakage. If so, immediately re-coolant the pipes—and after re-coolant, don’t forget to repair the pipes.
For ordinary users, the above symptoms can provide a preliminary diagnosis, but the most accurate method is to have a professional check the system pressure with a pressure gauge.
In cooling mode, the normal pressure should be between 0.4-0.5 MPa. If it is below 0.45 MPa, it indicates a lack of refrigerant.